Ambulance equipment list and maintenance checklist

Ambulance Owner Association (AOA) · Updated

Quick answer

What an ambulance should carry depends on its AIS-125 type. AIS-125 (Part 2, 2014) recommends the medical equipment for Types A to D, from a first aid kit and 2.2-litre oxygen cylinder on a Type A to a defibrillator, ventilator and monitor on a Type D. Check the vehicle and equipment at every shift, keep oxygen above half, disinfect the patient cabin after every patient, and record everything in a signed logbook.

Key facts

  • AIS-125 (Part 2), "Medical Equipment for Road Ambulances" (ARAI/MoRTH, August 2014), lists recommended equipment for Types A, B, C and D; it is a guideline, not part of vehicle type approval.
  • Under AIS-125 (Part 2) a Type C (BLS) ambulance should have at least two 10-litre stationary oxygen cylinders and every type should carry a 2.2-litre portable cylinder.
  • The MoHFW Operational Guidelines for National Ambulance Service (NAS) 2026 ask EMTs to keep oxygen at 90% of storage capacity and to swap in a full cylinder once it drops below 50%.
  • Rule 15 of the Gas Cylinders Rules, 2016 bans oil or similar lubricant on cylinder valves and fittings and bars exposing cylinders to high temperature or the sun.
  • NAS 2026 says the patient cabin should be disinfected with 1% sodium hypochlorite after every patient transport, with a 30-minute contact time.

What equipment must an ambulance carry in India?

The equipment an ambulance should carry is set by its type under AIS-125, the National Ambulance Code: Part 1 makes certain fittings compulsory for type approval (stretcher, seat belts, fire extinguishers, oxygen mounting), and Part 2 recommends the medical equipment for each of Types A, B, C and D.

It helps to separate the two layers:

  • Built into the vehicle (AIS-125 Part 1): main stretcher with undercarriage and patient straps on Types B, C and D; a mounting for a portable 2.2-litre oxygen cylinder, a hook for infusions and storage for a first aid and nursing kit on Types B, C and D (clause 6.2); two 2 kg fire extinguishers on Types C and D (clause 4.4.2); a lockable drugs compartment and wash basin on Types C and D. These are checked when the builder gets type approval under Rule 125-F of the Central Motor Vehicles Rules.
  • Carried medical equipment (AIS-125 Part 2): Part 2 says its Tables 9 to 19 are "recommendatory", that medical equipment is not part of vehicle type approval, and that it "may not be supplied by the ambulance manufacturer". Where a table shows "X", the quantity can be set by the state or district.

In practice, the Part 2 list becomes binding when a contract adopts it. The MoHFW Operational Guidelines for National Ambulance Service (NAS) 2026 say medical equipment in ambulances "shall comply with AIS-125" and give their own list of 17 items for BLS and 28 for ALS ambulances. Hospital tie-ups and government tenders usually attach an equipment list, so read it before you sign. If you are not sure which type your vehicle is, our AIS-125 types guide in the related list explains each one.

Part 2 also gives a planning weight for all sanitary, medical and technical items: 115 kg for a Type B, 225 kg for a Type C and 260 kg for a Type D. Keep this in mind before adding extra boxes, because the gross vehicle weight on your papers already includes it.

What is the ambulance equipment list for each type under AIS-125?

The tables below are taken from AIS-125 (Part 2), Tables 9 to 19. A number is the recommended quantity, "X" means the quantity depends on local needs, and "-" means not listed for that type.

Patient handling and immobilisation (Tables 9 and 10)

ItemBCD
Main stretcher with undercarriage (AIS-125 Part 1)111
Pick-up (scoop) stretcher-11
Vacuum mattress-XX
Transfer mattress or carrying sheetXXX
Long spine board with head immobiliser and straps-XX
Fracture immobilisation set-11
Cervical collar set-11
Extrication device or short spine board-11

Oxygen, airway and suction (Table 11)

ItemABCD
Stationary oxygenXXAt least 2 cylinders of 10 L water capacityA 46.7 L and a 10 L water-capacity cylinder
Portable oxygen, 2.2 L water-capacity aluminium cylinder1111
Resuscitator with oxygen inlet, masks and airwaysXX11
Mouth-to-mask ventilator with oxygen inlet11XX
Electric portable suction (at least 30 L/min, 600 mm vacuum)XX11
Manual portable suction1111

Cylinders are to be made to IS 7285 and certified by the Chief Controller of Explosives (PESO), filled to a maximum of 150 kgf/cm².

Diagnostics and infusion (Tables 12 to 14)

ItemABCD
Manual BP monitor (cuffs 10 to 66 cm)--11
Automatic BP monitor--XX
Pulse oximeter, stethoscope, thermometer, blood sugar device, diagnostic light--1 each1 each
Pain relief drugs--XX
Infusion solutions (litres)--44
Injection and infusion sets--22
Infusion mounting1122
Pressure infusion device---1

Advanced life support items (Table 15)

ItemCD
Defibrillator with rhythm and patient data recordingX1
Cardiac monitorX1
Nebulisation apparatus11
Emergency and transport ventilator (ISO 10651-3), adjustable PEEP valve, capnometer-1 each
Thorax drainage kit, volumetric infusion device, central vein catheters-1 each

Safety, rescue and communication (Tables 18 and 19)

ItemABCD
Cleaning and disinfection material1111
Seat belt cutter1111
Warning triangles2222
Spotlight1111
ABC fire extinguisher, minimum 2 kg (IS 13849 or IS 2171)1122
Rescue toolsXXXX
Mobile phone or radio access to the public network1-11
Intercom between driver and patient compartment--11

Part 2 also lists wound and burn dressings, sharps container, vomit bags, gloves, clinical waste bags and disposable stretcher sheets (Table 16), and personal protective equipment for each crew member, including a high-visibility reflective jacket (Table 17). It adds that an ambulance used for crash rescue should carry powered cutters, spreaders and rams, or be backed by a rescue vehicle that does.

What should be checked on an ambulance every day?

Every shift should start with two checks: the driver checks the vehicle and the EMT or attendant checks the medical equipment, oxygen and supplies, and both sign the logbook. The NAS 2026 guidelines say "the EMT on duty should check all equipment before every shift" and that the driver should check siren, communication device, headlights, emergency lights, brake lights, patient-compartment lights, wipers and air conditioning before taking over.

AreaDaily check (start of every shift)Who
Engine and fluidsEngine oil, brake fluid, coolant, fuel level; no leaks under the vehicleDriver
TyresPressure, visible cuts or bulges, spare tyre and jack presentDriver
Lights and warningsHeadlights, indicators, brake lights, beacon or light bar, siren in all tones, PA systemDriver
Cab and doorsWipers and washer, horn, mirrors, all doors lock, door-open warning worksDriver
OxygenPressure gauge of every cylinder; spare portable cylinder full; regulator and flowmeter work; no hissing at jointsEMT
SuctionElectric unit charged and creates vacuum; manual unit present; clean canister and tubingEMT
Monitors and defibrillatorSwitch on, battery charged, self-test passed, pads and electrodes in dateEMT
StretcherLocks into the floor mount, wheels and brakes work, straps present, clean sheetEMT and driver
Consumables and drugsRestock items used in the last shift; check for near-expiry itemsEMT
CleanlinessCabin cleaned and disinfected; waste bags and sharps box not overfullEMT
Safety kitFire extinguishers in place with gauge in the green, warning triangles, torch, seat belt cutterDriver

NAS 2026 treats missing life-saving equipment seriously: lack of medical oxygen, a bag and mask device, ventilator, monitor, defibrillator, suction pump or infusion pump "will warrant de-rostering the ambulance" in a government-contracted fleet until it is replaced or repaired. For a private operator the cost is reputation instead of penalty, but the logic is the same: do not go on duty without them.

What should be checked weekly, monthly and at each service?

Weekly and monthly checks catch slower problems such as battery wear, loose fittings and expiring stock, while the service schedule follows kilometres run. NAS 2026 gives an illustrative preventive maintenance schedule, and says owners should also follow the manufacturer's instruction manual and adjust for local conditions.

Weekly and monthly (good practice for owners)

FrequencyVehicleEquipment and cabin
WeeklyBattery terminals clean and tight; extra medical battery charged; tyre tread and wheel nuts; air filter in dusty areasTest-run suction and nebuliser; check stretcher locks and mount bolts; check cabinets and drawers latch; deep clean of the cabin
MonthlyBrake pads, suspension noises, wiper blades, AC performance, all reflective markings intactCount full stock against the list; check expiry dates of drugs and consumables; inspect oxygen hoses and outlets; check fire extinguisher pressure and seal
Yearly or as the maker saysFitness certificate, insurance and permit renewals; PUCCalibration and servicing of monitors, defibrillator and ventilator by the supplier; oxygen cylinder test dates

Service schedule by kilometres (NAS 2026, section 6.2, illustrative)

IntervalService points
DailyLights, signals, warning systems, engine oil, brake oil, gear oil, coolant, fuel, tyre pressure, air conditioning, heating, wipers, brakes, overall engine condition
5,000 kmChange oil, oil filter and air filter; check suspension, belts and alternator; brake wear; battery load test; plus the daily list
25,000 kmAll of the above plus suspension and differential, fuel filter, brake pads and rotors
50,000 kmAll of the above plus replace belts, fuel filters and transmission fluid
100,000 kmAll of the above plus replace AC compressor and dryers, hoses and oil bypass lines, repack bearings, replace shock absorbers

For medical devices, NAS 2026 asks that calibration, maintenance and spares be covered through an AMC or CMC with the manufacturer or another competent agency. AIS-125 (Part 2) also says the device manufacturer should supply preventive maintenance instructions; keep them with the equipment file.

How should oxygen cylinders be handled and stored in an ambulance?

Keep oxygen cylinders upright and strapped in their brackets, keep valves closed when not in use, keep oil, grease and flames away, never expose them to heat or direct sun, and use only certified cylinders, valves and regulators. Oxygen does not burn on its own, but it makes other materials burn much faster and hotter.

What the rules say

  • Gas Cylinders Rules, 2016, Rule 15 (general precautions): cylinders, valves, fittings and identification colours must always be maintained in good condition; "No oil or similar lubricant shall be used on any valves or other fittings of any cylinder"; no cylinder shall be exposed to high temperature or to the sun, or stored with flammable or explosive material; valves must be kept securely closed to prevent leaks; a leaking valve that cannot be stopped by tightening must be moved to an open space and the filler informed.
  • AIS-125 (Part 2), clause 4.8: all compressed gas cylinders larger than 2.2 litres water capacity "must be stored and used in an upright position with the valve end up", unless designed and certified for horizontal use; cylinders to IS 7285 certified by the Chief Controller of Explosives; pin-index valves to IS 3224; flowmeters of dial type without floats; the cylinder compartment should have a safe place to rest the regulator while changing cylinders; and "ambulances should not be operated with lesser number of cylinders" than specified.
  • NAS 2026: the EMT should keep at least 90% of total oxygen storage capacity, and replace a cylinder with a full one once storage falls below 50%.

Practical handling checklist

  1. Accept cylinders only from a licensed filler, with the correct medical oxygen colour marking and a legible test date.
  2. Carry cylinders with a trolley or both hands; never roll, drop or lift them by the valve.
  3. Strap every cylinder in its bracket before the vehicle moves. A loose cylinder in a crash is dangerous.
  4. Wash hands of hand cream or oil before touching the valve or regulator; never use grease or oily cloth on fittings.
  5. Open the valve slowly, standing to one side of the regulator.
  6. Check for leaks by listening, and with soapy water if your supplier recommends it; never with a flame.
  7. No smoking, matches or sparks in or near the vehicle when oxygen is in use; keep the cabin ventilated.
  8. Close the cylinder valve at the end of use and when parked; do not leave the regulator under pressure overnight.
  9. Store spare cylinders in a shaded, ventilated place, chained upright, with full and empty cylinders kept apart and labelled.
  10. Return damaged or leaking cylinders to the filler; do not repair valves yourself.

Keep the cylinder supplier's phone number in the vehicle file, and note each refill in the logbook so you can see consumption per trip.

How should an ambulance be cleaned between patients?

Clean and disinfect every surface the patient or crew touched after every patient transfer, using 1% sodium hypochlorite or an alcohol-based disinfectant for equipment, and do a full clean every morning and evening. This is the method in section 9.3 of the NAS 2026 guidelines from the Ministry of Health and Family Welfare.

Step by step (NAS 2026, section 9.3)

  1. Wear gloves and an N95 mask while cleaning.
  2. Remove used linen and disposables; put infectious waste in a biohazard bag and hand it to the hospital for disposal under its policy.
  3. Damp-wipe all horizontal, vertical and contact surfaces with a cotton or microfibre cloth soaked in 1% sodium hypochlorite: stretcher, rails, infusion pumps, IV poles, monitor cables, phone, countertops and sharps container.
  4. Spot-clean walls when visibly soiled with a disinfectant-detergent, and windows with glass cleaner.
  5. Allow 30 minutes of contact time, then let surfaces air-dry.
  6. Damp-mop the floor with 1% sodium hypochlorite; change the mop water after each cleaning cycle.
  7. Do not dip a used cloth back into the disinfectant solution.
  8. Clean reusable patient equipment before using it on another patient. NAS lists 1% sodium hypochlorite or alcohol-based disinfectants such as ethanol or isopropyl alcohol at 60 to 80%, at least once daily and after every patient contact.
  9. Remove gloves, dispose of them as biomedical waste, and clean your hands immediately.

Blood and body fluid spills

NAS 2026 says to wear gloves, a gown and eye protection, soak up the spill with absorbent pads or a spill kit, put contaminated material in a leak-proof biohazard bag, then clean and disinfect the area. Keep a stocked spill kit in every vehicle.

Things owners can do

  • Keep alcohol hand rub in the cabin at all times; NAS calls hand hygiene "the single most important practice" to reduce infection.
  • Follow the label on any disinfectant for dilution; sodium hypochlorite is corrosive, so wipe metal fittings and electronics as the device maker advises.
  • AIS-125 (Part 1) requires the Type C and D cabin lining to be non-permeable and disinfectant-resistant; repair torn lining or sealant, because fluid that gets behind panels cannot be cleaned.
  • Segregate biomedical waste by colour-coded bags as per the current Bio-Medical Waste Management Rules, and never mix sharps with ordinary waste.

What records should an ambulance owner keep?

Keep three sets of records: a shift checklist and inventory log signed at every handover, a trip logbook, and a vehicle and equipment file with documents, service history and certificates. NAS 2026 asks crews to "sign the checklist at the beginning of their duty and hand it over to the next ambulance personnel", and asks drivers to keep a logbook of every trip.

RecordWhat to writeWhy it matters
Shift checklistDate, shift, names, each item checked, faults found, signatures of outgoing and incoming crewShows the vehicle was fit for service; settles disputes about who broke or used what
Inventory and expiry logStock of each drug and consumable, items used, near-expiry dates, reorder dateNAS asks providers to replace near-expiry items before expiry
Oxygen logCylinder number, refill date, pressure at start and end of shiftLets you plan refills and spot leaks
Trip logbookPatient name, pick-up address, travel time, kilometres, service given (NAS Annexure 3)Billing, insurance, tax records, and answering complaints
Cleaning logTime of disinfection after each patient, product used, who cleanedProof of infection control for hospitals and tenders
Vehicle fileRC, insurance, fitness, permit, PUC, AIS-125 type-approval papers, service billsNeeded at RTO checks, renewals, claims and resale
Equipment filePurchase bills, warranties, AMC, calibration certificates, maintenance instructionsAIS-125 Part 2 says operating and maintenance instructions and service records should accompany the product

A tidy file also raises your resale value. Buyers on the second-hand ambulance section ask about service history and kilometres, and a seller who can show records answers those questions quickly. When you register your ambulance on AOA, you can upload its documents in one place.

How do AOA members share equipment and maintenance tips?

AOA members share practical tips in the community feed of the free AOA app, where owners and drivers post a problem or experience with a photo and others like and comment. Common topics include which suction unit lasts, how to stop a cylinder bracket rattling, where to get oxygen refilled at night, and how to pass a fitness inspection.

  • Post a photo of a fault or a fitting you are unsure about, and ask how others solved it.
  • Read the daily tips in the app for short maintenance and safety reminders.
  • Follow ambulance news on the AOA news page, such as the 2026 MoRTH draft on rescue equipment for Type B, C and D ambulances.
  • Buy or sell a used ambulance with filters by type, city, brand and price, and contact sellers through "Connect Now".

Before acting on any tip, check it against your vehicle maker's manual and your equipment supplier's instructions. You can download the AOA app from the Play Store; it is free for owners, drivers and guests.

हिंदी सारांश: एम्बुलेंस उपकरण और जाँच सूची

एम्बुलेंस में कौन-सा उपकरण होना चाहिए, यह AIS-125 के टाइप पर निर्भर करता है। AIS-125 (Part 2) टाइप A से D तक के लिए उपकरणों की सिफारिशी सूची देता है: हर टाइप में 2.2 लीटर का पोर्टेबल ऑक्सीजन सिलेंडर, टाइप C में कम से कम दो 10 लीटर के सिलेंडर, और टाइप D में डिफिब्रिलेटर, मॉनिटर और वेंटिलेटर। हर शिफ्ट से पहले ड्राइवर गाड़ी और EMT उपकरण जाँचें और लॉगबुक पर हस्ताक्षर करें। NAS 2026 के अनुसार ऑक्सीजन 50% से कम होने पर भरा सिलेंडर लगाएँ। गैस सिलेंडर नियम 2016 के अनुसार वाल्व पर तेल या ग्रीस न लगाएँ और सिलेंडर को धूप या गर्मी से दूर रखें। हर मरीज़ के बाद केबिन को 1% सोडियम हाइपोक्लोराइट से साफ करें।

Frequently asked questions

Is the AIS-125 Part 2 equipment list compulsory?

AIS-125 (Part 2) describes its equipment tables as recommendatory and says medical equipment is not part of vehicle type approval. It becomes binding when a contract, tender or state scheme adopts it; the MoHFW NAS 2026 guidelines, for example, say ambulance medical equipment shall comply with AIS-125. Fittings such as the stretcher, seat belts and fire extinguishers are part of AIS-125 Part 1 type approval.

How many oxygen cylinders should an ambulance have?

AIS-125 (Part 2) recommends one 2.2-litre portable cylinder for every type, at least two 10-litre stationary cylinders for a Type C (BLS) ambulance, and a 46.7-litre plus a 10-litre stationary cylinder for a Type D (ALS) ambulance. It says ambulances should not run with fewer cylinders than specified.

When should an ambulance oxygen cylinder be changed?

The MoHFW NAS 2026 guidelines ask the EMT to keep at least 90% of total oxygen storage capacity and to replace the cylinder with a 100% full one if storage drops below 50%. Check the gauge at the start of every shift and after long trips, and record refills in the logbook.

Can oxygen cylinders be laid flat in an ambulance?

AIS-125 (Part 2) says compressed gas cylinders larger than 2.2 litres water capacity must be stored and used upright with the valve end up, unless the cylinder is specially designed and certified for horizontal use. Small 2.2-litre portable cylinders are excepted. Whatever the size, the cylinder must be strapped in a bracket so it cannot move.

Which disinfectant should be used to clean an ambulance?

The MoHFW NAS 2026 guidelines recommend 1% sodium hypochlorite solution for surfaces and floors, with 30 minutes of contact time before air drying, and 1% sodium hypochlorite or alcohol-based disinfectants of 60 to 80% ethanol or isopropyl alcohol for equipment. Follow the equipment maker's advice for electronics and metal parts.

What does a Type D ALS ambulance need that a Type C does not?

Under AIS-125 (Part 2), a Type D adds a defibrillator with recording, cardiac monitor, emergency and transport ventilator, adjustable PEEP valve, capnometer, pressure infusion device, volumetric infusion device, thorax drainage kit and central vein catheters, plus a larger 46.7-litre oxygen cylinder. AIS-125 Part 1 also requires air conditioning in Type D.

Sources

Rules and prices change: check the official source listed below before you decide.

Read next